Failure
|
Cause
|
Remedy
|
| The ZON MARK 2, fully connected, fails to operate at all. |
The valve of the gas tank is not open. |
Open the value. |
| The interval regulator is not opened. |
Open it by turning into the + mark direction; if the detonations are too frequent, turn it a little to the - mark. |
| The gas tank is empty or has too little pressure. |
Connect a new gas tank. |
| The gas valve, no. 7042, can't be opened. This is possible if the ZON MARK 2 has not been used for some time. |
With two fingers, pull up the hinged clip, no. 7042M, two or three times. |
| Leaks. |
The coupling nut gas regulator is not tight enough. |
Tighten coupling nut with suitable spanner. |
| The hose from the regulator-unit to the ZON MARK 2 has been damaged. |
Renew the hose.
A fast method to trace a leak in the gas regulator is to check it with a leakage spray. |
| Diaphragm leaks along the plate rim. |
Repair should be carried out by the dealer. |
| The ZON MARK 2 operates, but there is no explosion or sound. |
Ignition gives a weak spark or no spark at all. |
Check the electrode, no. 7052F. It is possible that the porcelain or the mass point is broken; if so, renew.
Distance mass point - electrode: is not correct. This must be 2.5 - 3 mm. If not so, adjust with a small pair of pincers.
Spark bolt, no. 7262: is loose. Turn up or down until the tripper, no. 7226, is free from the main body, no. 7112. the distance is 1 - 1.5 mm, then tighten the nut firmly.
Note: The spark bolt, no. 7262, must be in horizontal contact with the piezo-element, no 7052A.
Piezo-element, no. 7052: replace.
Piezo-element, no. 7052A, and/or electrode, no. 7052F are wet. Dry both well. |
| The wind is too strong; gas/air mixture is disturbed. |
Place the ZON MARK 2 down wind or, if possible, place it out of the wind or behind a screen. |
| Gas mixture is not good. |
Gas mixture in the gas tank is not good, replace gas tank.
Preferably use propane gas. |
| The ZON MARK 2 works, but the diaphragm gland, no. 7142, remains in the top position. |
The gas valve-holder, no. 7042F, is blocked or partially blocked. |
Clean opening with small piece of wire no morethan 0.6 mm thick. |
| The gas valve, no. 7042, is not open. |
With two fingers, pull up the hinged clip, no. 7042M, two or three times. |
| Gas valve, no. 7042, stays open: diaphragm gland, no. 7142, remains above. The gas valve, no. 7042, can't be opened or sufficiently opened. |
Torsion spring, no. 7152A and/or no. 7152B are broken. If so, replace.
Lifting level must be 1 - 2 mm.
The measures which have to be taken for this, must be carried out by the dealer. |
| The ZON MARK 2 works, but gives dull explosions. |
Wind is too strong; gas/air mixture is disturbed. |
Place the ZON MARK 2 down wind, or if possible, place it out of the wind or behind a screen. |
| Telescopic megaphone not or partially pulled out. |
Pull out to full extension. |