Failure
|
Cause
|
Remedy
|
| The ZON MARK 3, fully connected, fails to operate at all. |
The valve of the gas tank is not open. |
Open the valve. |
| The hose fracture protector button (red) has not been pushed. |
Push the red button on the hose fracture protector one or more times. |
| The battery cable has not been connected properly. |
Make sure that the connection terminals are connected properly. The black terminal should be connected to the negative (-) pole and the red terminal to the positive (+) pole of the battery. |
| The battery does not have enough power. |
Connect a new battery, or recharge the present battery using proper equipment. |
| The gas tank is empty or has too little pressure. |
Connect a new gas tank. |
| The gas valve will not operate. |
Check the connection points. If they are properly connected, call the dealer for repair. |
| The knobs (DT and SR) are not on the right setting. |
DT1: Fast (1e explosion after +/- 45 sec.).
DT2: Medium (1e explosion after +/- 75 sec.).
DT3: Slow (1e explosion after +/- 135 sec.). |
| The ZON MARK 3 Leaks. |
The coupling nut gas regulator is not tight enough. |
Tighten coupling nut with suitable spanner. |
| The hose from the regulator-unit to the ZON MARK 3 has been damaged. |
Replace the hose.
A fast method to trace a leak in the gas regulator is to check it with a leakage spray. |
| The ZON MARK 3 operates, but there is no explosion or sound. |
The hose fracture protector button (red) has not been pushed. |
Push the red button on the hose fracture protector one or more times. |
| Ignition gives a weak spark or no spark at all. |
Check the electrode (no. 91536) It is possible that the porcelain or the mass point is broken; if so replace. Electrode is wet dry it well. |
| Poor gas mixture. |
Replace gas tank.
Preferably use propane gas. |
| The gas valve is blocked or partially blocked. |
Open up blockage using a thin wire of approximately 0.6 mm diameter (wire from a steel brush). |
| The ZON MARK 3 works, but gives dull explosions. |
Wind is too strong gas/air mixture is disturbed. |
Place the ZON MARK 3 downwind or, if possible, place it out of the wind, or behind a screen. |
| Telescopic megaphone is not pulled out or is only partially pulled out. |
Pull out to full extension. |